Salicru SPS 2000 ADV RT2 B1
Uninterruptible Power Systems (UPS) from 2000 VA Line-interactive sine-wave with tower/rack format (0’)
Salicru’s SPS ADVANCE RT2 series is a range of UPS featuring line interactive technology with sine-wave output voltage and convertible tower/rack format, the height being only 2U for all power ratings. In addition, its output power factor of 0.9 and compatibility with APFC (active power factor correction) type loads make it the best option for any type of load that requires protection.
In terms of communications, it features an RS-232/USB interface (compatible with HID protocol) and a smart slot that can optionally hold an SNMP card, MODBUS or potential-free contacts; also available are software packages for local or virtual monitoring and management of protected devices
And other outstanding features include: solutions for applications with long backup (by means of equipment with extra chargers and additional battery modules), swivel mount display and adapters (pedestal and lugs) for placing in tower or rack formats and programmable outputs (critical/non-critical loads) to extend the available backup
The power range for the SPS ADVANCE RT2 series is: 800, 1,100, 1,500, 2,000 and 3,000 VA
Applications: Flexibility and versatility in the protection of IT environments
The features of the SPS ADVANCE RT2 series make it a versatile solution for protecting a wide range of IT equipment such as basic servers, routers, switches, hubs and point-of-sale with high power density requirements and/or rack installation of servers/ communications.
Technical Specifications
| Technology | |
|---|---|
| Technology Type | Line-interactive |
| Format | |
| Format Type | Convertible tower/rack (2U) |
| Input | |
| Rated Voltage | 208 / 220 / 230 / 240 V |
| Voltage Range (100% Load) | 170 ÷ 280 V |
| Stabiliser | AVR (Buck & Boost) |
| Rated Frequency | 50 / 60 Hz (auto-detection) |
| Frequency Range | ±5 Hz |
| Autodetection of Frequency | Yes |
| Protection | Fuse (800/1100) or resettable thermal cutoff (1500/2000/3000) |
| Output | |
| Power Factor | 0.9 |
| Rated Voltage | 208 / 220 / 230 / 240 V |
| Voltage Accuracy (Battery Mode) | ±1.5% |
| Power (VA/W) | 2000 / 1800 |
| Total Harmonic Distortion (THDv) | <2% linear load / <5% non-linear load |
| Waveform (Battery Mode) | Pure sine wave |
| Frequency | 50/60 Hz (same as input) |
| Frequency Accuracy (Battery Mode) | ±0.1Hz |
| Admissible Overloads in Battery Mode | <120% off at 1 min / <150% off at 10 s |
| Admissible Overloads in In-line Mode | <120% off at 5 min / <150% off at 10 s / >150%: 1 s |
| Socket Type | IEC |
| Number of Sockets | 8 |
| Programmable Sockets | Yes, for critical / non-critical loads (4/4) |
| Battery | |
| Battery Type | Not included, Pb-Ca sealed, AGM, maintenance-free |
| Charge Type | I/U (constant current / constant voltage) |
| Recharge Time | 4 hours to 90% |
| Battery Test | Automatic on every start + once per week |
| Charger | |
| Temperature Voltage Compensation | Yes |
| Communication | |
| Ports | RS-232 / USB-HID |
| Intelligent Slot | Slot for SNMP / potential-free contacts / MODBUS |
| Monitoring Software | For Windows, Linux and Mac |
| Indications | |
| Type | LCD + Keypad |
| Values | Voltage, power, input/output frequency, battery voltage, battery charge %, load %, operating mode, fault, discharge time, mute |
| Operating Modes | Normal / Stabilisation (AVR) / Battery / Fault |
| Alarm | Output battery mode, polarity, low battery, charger failure and overload |
| Audible | Every 10 s for battery operation, every 2 s for low battery/polarity, every 1 s for overcharge, continuous for fault |
| Failure | LCD Display |
| Other Functions | |
| Cold Start | Yes |
| Emergency Stop (EPO) | Yes |
| ADSL/Fax/Modem Protection | Yes |
| Green Function | Yes, automatic stop in battery mode with load <5% |
| Smart Fan Speed | Yes |
| Site Wiring Fault | Yes, detects phase-neutral rotation and/or absence of earth |
| General | |
| Operating Temperature | 0°C ÷ 40°C |
| Relative Humidity | Up to 95%, non-condensing |
| Maximum Operating Altitude | 2,400 masl (power degradation up to 5,000 m) |
| Acoustic Noise at 1 Metre | <45 dB |
| Standards | |
| Safety | EN IEC 62040-1 |
| Electromagnetic Compatibility (EMC) | EN IEC 62040-2 (C2) |
| Operation | EN IEC 62040-3 |
| Corporate Certification | ISO 9001, ISO 14001, ISO 45001 |
| Dimensions | |
| Depth | 410 mm |
| Width | 438 mm |
| Height | 88 mm |
| Weight | |
| Weight | 11 kg |
Performances
- Line-interactive technology with sine-wave output.
- Permanent AVR stabilisation.
- Output power factor PF = 0.9.
- Control panel with swivel mount LCD display and keypad.
- Convertible tower/rack format (2U).
- Includes pedestal (pedestal mount) and lugs (rack mount).
- Backup extensions available for all power ratings.
- UPS models with extra charger for backup extensions.
- RS-232 / USB-HID interface.
- Downloadable monitoring software for Windows, Linux, and Mac.
- Smart slot for SNMP / potential-free contacts / MODBUS.
- ADSL / fax / modem protection.
- EPO – Emergency Power Off.
- Programmable outputs for critical / non-critical loads.
- Manual and automatic battery test.
- Smart battery charger to shorten average recharging times.
- Battery recharging with device turned off.
- Rack rails for 400–1000 mm deep cabinets included.