Salicru SLC-8000-TWIN RT2 B1
8000 VA On-line double-conversion tower/rack Uninterruptible Power Systems (UPS) (0’)
Salicru’s SLC TWIN RT2 series models are uninterruptible power supplies with unrivalled electrical protection features for critical server environments. Their dual tower/rack format offers physical adaptability to any site and, together with the built-in PDU strip, provides maximum ease of connection of the loads to be protected. In addition, their unity output power factor (VA=W) increases the power density delivered and reduces the space required for the installation of the UPS.
The LCD screen is swivel-mounted according to the mounting format chosen for ease of handling. In terms of serial communications, they feature USB, RS-232 and relay interfaces, as well as a smart slot to optionally accommodate an SNMP card, MODBUS or potential-free contacts; also available are software packages for local or virtual monitoring and management of the protected devices.
For applications that require extended backup, additional battery modules and/or solutions with extra charger can be installed. And for applications that require redundant protection or increase the need for power, there is the option of connecting up to 3 devices in parallel.
Applications: Guaranteed operability for IT environments
Numerous environments can be protected by Salicru’s SLC TWIN RT2 series UPSs, such as virtualised or non-virtualised server systems, voice and data networks, ERP systems, CRM solutions, document management, etc., all of whose operability depends on the reliability of the electrical supply that powers them.
Technical Specifications
| Technology | |
|---|---|
| Technology Type | On-line double-conversion |
| Format | |
| Format Type | Convertible tower/rack |
| Input | |
| Voltage | 220 / 230 / 240 V |
| Voltage Range | 110 ÷ 300 V up to 50% load |
| Rated Frequency | 50 / 60 Hz (auto-detection) |
| Frequency Range | ±4 Hz |
| Total Harmonic Distortion (THDi) | ≤4% |
| Power Factor | >0.99 at 100% load / 0.97 at 50% load |
| Output | |
| Power Factor | 1 (2) |
| Voltage | 208 / 220 / 230 / 240 V |
| Static Accuracy | ±1% |
| Power (VA/W) | 8000 / 8000 |
| Total Harmonic Distortion (THDv) – Linear Load | <1% |
| Total Harmonic Distortion (THDv) – Non-linear Load | <4% |
| Synchronised Frequency | ±4 Hz |
| Frequency Accuracy (Battery Mode) | ±0.1 Hz |
| Total Performance in On-line Mode | ≥93 ÷ 94% |
| Admissible Overloads | <110% for 10 min / <130% for 1 min / >130% for 1 sec |
| Socket Type | Terminals + PDU |
| Parallel | Yes, up to 3 units (3) |
| Static Bypass | |
| Voltage | 208 / 220 / 230 / 240 V (1) |
| Frequency Range | 50 / 60 Hz ±4 Hz |
| Battery | |
| Protection | Against power surges, undervoltages, and alternating current components |
| Battery Type | Not included, Pb-Ca sealed, AGM, maintenance-free |
| Charge Type | I/U (constant current / constant voltage) |
| Recharge Time | 7 ÷ 9 hours to 90% |
| Charger | |
| Temperature Voltage Compensation | Yes |
| Communication | |
| Ports | USB / RS-232 / Relay |
| Intelligent Slot | Smart slot for SNMP / potential-free contacts / MODBUS |
| Monitoring Software | Yes, for Windows, Linux, and Mac |
| Other Functions | |
| Cold Start (Start-up from Batteries) | Yes |
| Emergency Stop (EPO) | Yes |
| Operating Modes | |
| Frequency Converter (CVCF) | Yes (4) |
| General | |
| Operating Temperature | 0°C ÷ +40°C |
| Relative Humidity | Up to 95%, non-condensing |
| Maximum Operating Altitude | 2,400 masl (power degradation up to 5,000 m) |
| Acoustic Noise at 1 Metre | <60 dB |
| Standards | |
| Safety | EN-IEC 62040-1 |
| Electromagnetic Compatibility (EMC) | EN 62040-2 (C3) |
| Operation | VFI-SS-11 (EN-62040-3) |
| Corporate Certification | ISO 9001, ISO 14001, ISO 45001 |
| Dimensions | |
| Depth | 630 mm |
| Width | 438 mm |
| Height | 88 mm |
| Weight | |
| Weight | 20 kg |
Notes:
- (1) 90% power reduction for 208 V devices
- (2) Except for devices with extended backup
- (3) 90% power reduction
- (4) 60% power reduction
- On-line double-conversion technology.
- Output power factor PF=1.(1)
- Convertible tower/rack format.
Control panel with swivel mount LCD display and keypad. ?Includes pedestal (pedestal mount) and lugs (rack mount). ?Backup extensions available for all power ratings. ?UPS models with extra charger for backup extensions. ?RS-232, USB and relay communication interfaces. ?Downloadable monitoring software for Windows, Linux and Mac. ?Smart slot for SNMP/potential-free contacts/MODBUS. ?Eco-mode operation. ?Parallelable up to 3 units. ?PDU strip for distribution of output loads. ?Frequency conversion function. ?SLC Greenergy solution.